1.
Sci Rep ; 8(1): 5592, 2018 04 04.
Artigo em Inglês | MEDLINE | ID: mdl-29618785

RESUMO

A novel device that can be used as a tunable support-free phase plate for transmission electron microscopy of weakly scattering specimens is described. The device relies on the generation of a controlled phase shift by the magnetic field of a segment of current-carrying wire that is oriented parallel or antiparallel to the electron beam. The validity of the concept is established using both experimental electron holographic measurements and a theoretical model based on Ampere's law. Computer simulations are used to illustrate the resulting contrast enhancement for studies of biological cells and macromolecules.

2.
Nanotechnology ; 24(46): 465701, 2013 Nov 22.
Artigo em Inglês | MEDLINE | ID: mdl-24149369

RESUMO

Fabrication of ultra-high aspect ratio exchangeable and customizable tips for atomic force microscopy (AFM) using lateral focused ion beam (FIB) milling is presented. While on-axis FIB milling does allow high aspect ratio (HAR) AFM tips to be defined, lateral milling gives far better flexibility in terms of defining the shape and size of the tip. Due to beam-induced deformation, it has so far not been possible to define HAR structures using lateral FIB milling. In this work we obtain aspect ratios of up to 45, with tip diameters down to 9 nm, by a deformation-suppressing writing strategy. Several FIB milling strategies for obtaining sharper tips are discussed. Finally, assembly of the HAR tips on a custom-designed probe as well as the first AFM scanning is shown.


Assuntos
Microscopia de Força Atômica/instrumentação , Nanotecnologia/instrumentação , Desenho de Equipamento
3.
Rev Sci Instrum ; 82(7): 076103, 2011 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-21806237

RESUMO

We introduce a highly compact fiber-optic Fabry-Pérot refractive index sensor integrated with a fluid channel that is fabricated directly near the tip of a 32 µm in diameter single-mode fiber taper. The focused ion beam technique is used to efficiently mill the microcavity from the fiber side and finely polish the end facets of the cavity with a high spatial resolution. It is found that a fringe visibility of over 15 dB can be achieved and that the sensor has a sensitivity of ~1731 nm/RIU (refractive index units) and a detection limit of ~5.78 × 10(-6) RIU. This miniature integrated all-in-fiber optofludic sensor may find use in minimal-invasive biomedical applications.